Refrigerant leaks, R-22 and newer refrigerants explained

acrepairfortworth.net

Refrigerant is the fluid that carries heat out of your house, and a central AC does not use it up. If the level is low, there is a leak somewhere, and that changes what a good repair looks like.

Need AC help now?
Call now to be connected with a local AC and heating company in Fort Worth.
(817) 623-4802

Refrigerant is the fluid that carries heat out of your house, and a central AC does not use it up. If the level is low, there is a leak somewhere, and that changes what a good repair looks like.

What refrigerant does in your AC

A central air conditioner moves heat rather than making cold. Refrigerant circulates in a sealed loop of copper line between the indoor evaporator coil and the outdoor unit. Inside, it absorbs heat from your house air. Outside, the compressor and condenser push that heat into the yard. The loop is closed, so under normal conditions the charge never wears out and never needs adding to.

That is the most important fact in this guide. If a technician tells you the system is low on refrigerant, the follow-up question is where it went. Adding refrigerant without finding and fixing the leak is a short-term patch that tends to repeat.

Signs of a refrigerant leak

  • The system runs but the air from the vents is only mildly cool, and it gets worse over days or weeks.
  • Ice forms on the copper line at the outdoor unit or on the indoor coil. Low pressure lets the coil get colder than freezing, so moisture on it turns to ice.
  • A hissing or bubbling sound near the coil or the lines.
  • Cooling that was fine in spring fades as outdoor temperatures climb in summer, because the weakened system cannot keep up with the load.
  • Higher electric bills with no change in how you use the house.

Several of these also describe a dirty filter, a dirty coil or a failing fan, so a diagnosis matters. The AC not cooling checklist covers the safe checks you can do first.

Where leaks tend to happen

Leaks usually show up at the evaporator coil, the outdoor coil, the line set joints, or the service valves. Coils in older systems can develop tiny pinhole leaks from corrosion. Vibration can loosen a fitting over time. A technician finds the leak with a pressure test, an electronic detector or a dye added to the system, then decides whether a repair makes sense. Many leaks in a coil are not practical to patch, and replacing a coil is the usual route. A local evaporator coil repair company can tell you which applies.

EPA Section 608: why a certified technician matters

Under Section 608 of the Clean Air Act, EPA requires technicians who maintain, service, repair or dispose of refrigerant-containing equipment to be certified by passing an EPA-approved test, in Type I, II, III or Universal categories. Section 608 certification does not expire. Apprentices are exempt only when closely and continually supervised by a certified technician.

EPA regulations also prohibit individuals from intentionally venting ozone-depleting substances or their substitutes while servicing or disposing of air-conditioning or refrigeration equipment, with only a few narrow exceptions such as small releases during good-faith recovery. In practice, that means refrigerant must be recovered, not released into the air. Homeowners should never open a refrigerant line, and any company working on the sealed system should be able to confirm that its technician holds Section 608 certification.

Texas licensing is separate

EPA certification covers the technician's handling of refrigerant. Texas adds a contractor license. Anyone offering air conditioning and refrigeration contracting services in Texas must hold an ACR contractor license from the Texas Department of Licensing and Regulation. TDLR offers an online license search that shows whether a person or business holds a license, plus a separate search for penalties and administrative orders. Our guide on how to check a TDLR license shows the steps. A company that holds a TDLR license and a certified technician together is what you want to see before anyone touches the refrigerant circuit.

R-22: the older refrigerant

For decades, residential AC systems used HCFC-22, known as R-22 or by a common brand name. EPA states that U.S. production and import of HCFC-22 has ended, and that owners of existing R-22 systems may keep using them for as long as necessary, supplied by recovered and reclaimed refrigerant. So an R-22 system is not illegal, and you are not required to replace it on any schedule.

What changes is the supply. With no new production, R-22 comes from recovered stock, and it costs more than newer refrigerants. A HomeGuide cost page, which gives national figures, lists installed R-22 at about $90 to $150 per pound and installed R410A at about $50 to $80 per pound. It also lists a recharge at $180 to $600 for R-22 units and $100 to $320 for R410A units. These are national figures, so local quotes may differ.

Newer refrigerants and the transition

Since the R-22 era, most residential equipment has used R410A. EPA's technology transitions rule sets a global warming potential limit of 700 for new residential and light commercial air conditioners and heat pumps, moving new equipment away from high-GWP refrigerants. The same EPA fact sheet says the rule does not restrict continued use of existing systems, which can be serviced and repaired through the end of their useful life.

For a homeowner, that means two things. If you buy a new system, it will use a refrigerant that meets the current rules, and the model will specify which one. And if you own a working older system, you can keep repairing it. The decision is financial, not regulatory.

A new system also cannot use the old refrigerant in the old coil. Refrigerants are not interchangeable in an existing sealed system, so a company will not simply swap one for another. If your outdoor unit and indoor coil are mismatched or very old, replacement may be cleaner than a repair. Our repair or replace guide explains how to weigh it.

What leak repair can cost

A HomeGuide cost page, using national figures, puts refrigerant leak repair, meaning the leak fix and refill, at about $200 to $1,500 per job. The wide spread comes from where the leak is. A loose fitting is a small job, while a leaking coil can approach the cost of replacing the part. The same source puts a general AC repair at $150 to $650 and a service call or diagnostic fee at $75 to $200. For a coil, HomeGuide lists replacement at about $400 to $2,400 per job. These are not local quotes and are not promises.

Ask any company that finds a leak to explain three things: where the leak is, whether it can be repaired or the part replaced, and what happens if you decline and only recharge the system. A refill without a fix may last through a season or only a few weeks. If the system is old and on R-22, the extra cost of refilling is part of the decision about replacing it. To see how companies handle this work, read our page on refrigerant leak repair in Fort Worth, and for the compressor side, AC compressor repair.

What you can do safely

  • Switch the system off at the thermostat if you see ice on the lines, and let it thaw. Running it frozen can damage the compressor.
  • Do not open, tap or cut any refrigerant line, and do not buy refrigerant to add yourself.
  • Keep a record of when the system was last charged and by whom. It helps the next technician.

Heat load across North Texas is high, so a leaking system tends to fail in the worst weather. The guide on getting an AC through a North Texas summer covers how to prepare. Homes in Keller, Burleson and the other towns we serve face the same issue.

Call now to be connected with a local AC and heating company in Fort Worth.
(817) 623-4802

AC Repair Fort Worth is a free referral service that connects you with independent local companies. We do not do the repair and do not set the price.

Frequently asked questions

Does an AC need refrigerant added every year?
No. Refrigerant circulates in a sealed loop and is not used up. If the charge is low, there is a leak, and the leak is what should be found and addressed.
Is it illegal to keep using an R-22 system?
No. EPA states that owners of existing R-22 systems may keep using them for as long as necessary, supplied by recovered and reclaimed refrigerant, although production and import of R-22 has ended.
Can I add refrigerant to my AC myself?
No. Refrigerant work requires EPA Section 608 certification, and venting refrigerant is prohibited. A homeowner should not open a refrigerant line or add refrigerant.
How much does refrigerant leak repair cost?
A HomeGuide cost page lists national figures of about $200 to $1,500 per job for the leak fix and refill. Actual cost depends on where the leak is and which part is involved.
Call now to be connected with a local AC and heating company in Fort Worth.
(817) 623-4802

Last updated:

☎ Call (817) 623-4802