Start with the simple things: the thermostat set to cool and below room temperature, a clean filter, open vents, and a breaker that has not tripped. If those are fine, ice on the coil or a weak outdoor unit points to a repair. Call the number on this page to be connected with a local AC company in River Oaks.

When the thermostat is the culprit
Sometimes the thermostat itself has failed or lost its wiring connection, and it never signals the AC to start. Signs include a blank screen with fresh batteries, a display that stays on but never clicks, or a reading that does not match the room. A technician can test the signal quickly and tell whether it needs replacing.
The blower is only half the story
If you can hear the air handler and feel air at the vents, the blower is working, and the question becomes whether that air is cold. If you hear nothing, check the thermostat and breaker. A silent blower with power can mean a failed motor or capacitor, which is a repair, not a setting.
Thawing safely
- Set the thermostat to off.
- Turn the fan to on so air moves across the coil.
- Let it run for several hours until the ice is gone.
- Replace the filter, then restart cooling.
If the ice returns, call; something else is wrong, and running the system on a frozen coil risks the compressor.
After a storm or an outage
Brief outages and surges are hard on the capacitor, contactor and control board. If the AC was fine yesterday and silent today, check for a tripped breaker, then the thermostat display. These parts are common failures after weather events, and a technician can test them quickly without much disruption.
What the technician measures
| Check | What it shows |
|---|---|
| Temperature drop across the coil | Whether cooling is adequate |
| Refrigerant pressures | Possible leak or restriction |
| Compressor amps | Compressor health |
Together these readings show whether a repair or a replacement conversation makes sense, and they give you something concrete to ask about before approving any work.
Who handles what in River Oaks
Texas requires anyone contracting for air conditioning and refrigeration work to hold an ACR contractor license from the Texas Department of Licensing and Regulation (TDLR). Ask for the license number and check it on TDLR's license search.
Anyone who opens a refrigerant circuit has to be EPA Section 608 certified, and venting refrigerant is not allowed, so leak work and recharges belong with a certified technician.
River Oaks' Building Inspections / Permits office is the office for building and mechanical permits in River Oaks; ask the contractor whether your job needs one.
River Oaks is in Oncor's delivery area: Oncor maintains the lines and restores outages (888-313-4747), while you buy power from the retail electric provider you chose.
Nearby, the same kind of help is available in Fort Worth, Sansom Park and White Settlement.